273 lines
6.9 KiB
C
273 lines
6.9 KiB
C
// SPDX-License-Identifier: GPL-2.0
|
|
/*
|
|
* Renesas RZ/G3S TSU Thermal Sensor Driver
|
|
*
|
|
* Copyright (C) 2024 Renesas Electronics Corporation
|
|
*/
|
|
|
|
#include <linux/bitfield.h>
|
|
#include <linux/delay.h>
|
|
#include <linux/iio/consumer.h>
|
|
#include <linux/io.h>
|
|
#include <linux/module.h>
|
|
#include <linux/platform_device.h>
|
|
#include <linux/pm_runtime.h>
|
|
#include <linux/reset.h>
|
|
#include <linux/thermal.h>
|
|
#include <linux/units.h>
|
|
|
|
#include "../thermal_hwmon.h"
|
|
|
|
#define TSU_SM 0x0
|
|
#define TSU_SM_EN BIT(0)
|
|
#define TSU_SM_OE BIT(1)
|
|
#define OTPTSUTRIM_REG(n) (0x18 + (n) * 0x4)
|
|
#define OTPTSUTRIM_EN_MASK BIT(31)
|
|
#define OTPTSUTRIM_MASK GENMASK(11, 0)
|
|
|
|
#define TSU_READ_STEPS 8
|
|
|
|
/* Default calibration values, if FUSE values are missing. */
|
|
#define SW_CALIB0_VAL 1297
|
|
#define SW_CALIB1_VAL 751
|
|
|
|
#define MCELSIUS(temp) ((temp) * MILLIDEGREE_PER_DEGREE)
|
|
|
|
/**
|
|
* struct rzg3s_thermal_priv - RZ/G3S thermal private data structure
|
|
* @base: TSU base address
|
|
* @dev: device pointer
|
|
* @tz: thermal zone pointer
|
|
* @rstc: reset control
|
|
* @channel: IIO channel to read the TSU
|
|
* @mode: current device mode
|
|
* @calib0: calibration value
|
|
* @calib1: calibration value
|
|
*/
|
|
struct rzg3s_thermal_priv {
|
|
void __iomem *base;
|
|
struct device *dev;
|
|
struct thermal_zone_device *tz;
|
|
struct reset_control *rstc;
|
|
struct iio_channel *channel;
|
|
enum thermal_device_mode mode;
|
|
u16 calib0;
|
|
u16 calib1;
|
|
};
|
|
|
|
static int rzg3s_thermal_get_temp(struct thermal_zone_device *tz, int *temp)
|
|
{
|
|
struct rzg3s_thermal_priv *priv = thermal_zone_device_priv(tz);
|
|
int ts_code_ave = 0;
|
|
|
|
if (priv->mode != THERMAL_DEVICE_ENABLED)
|
|
return -EAGAIN;
|
|
|
|
for (u8 i = 0; i < TSU_READ_STEPS; i++) {
|
|
int ret, val;
|
|
|
|
ret = iio_read_channel_raw(priv->channel, &val);
|
|
if (ret < 0)
|
|
return ret;
|
|
|
|
ts_code_ave += val;
|
|
/*
|
|
* According to the HW manual (Rev.1.10, section 40.4.4 Procedure for Measuring
|
|
* the Temperature) we need to wait here at leat 3us.
|
|
*/
|
|
usleep_range(5, 10);
|
|
}
|
|
|
|
ts_code_ave = DIV_ROUND_CLOSEST(MCELSIUS(ts_code_ave), TSU_READ_STEPS);
|
|
|
|
/*
|
|
* According to the HW manual (Rev.1.10, section 40.4.4 Procedure for Measuring the
|
|
* Temperature) the computation formula is as follows:
|
|
*
|
|
* Tj = (ts_code_ave - priv->calib1) * 165 / (priv->calib0 - priv->calib1) - 40
|
|
*
|
|
* Convert everything to milli Celsius before applying the formula to avoid
|
|
* losing precision.
|
|
*/
|
|
|
|
*temp = div_s64((s64)(ts_code_ave - MCELSIUS(priv->calib1)) * MCELSIUS(165),
|
|
MCELSIUS(priv->calib0 - priv->calib1)) - MCELSIUS(40);
|
|
|
|
/* Report it in milli degrees Celsius and round it up to 0.5 degrees Celsius. */
|
|
*temp = roundup(*temp, 500);
|
|
|
|
return 0;
|
|
}
|
|
|
|
static void rzg3s_thermal_set_mode(struct rzg3s_thermal_priv *priv,
|
|
enum thermal_device_mode mode)
|
|
{
|
|
struct device *dev = priv->dev;
|
|
int ret;
|
|
|
|
ret = pm_runtime_resume_and_get(dev);
|
|
if (ret)
|
|
return;
|
|
|
|
if (mode == THERMAL_DEVICE_DISABLED) {
|
|
writel(0, priv->base + TSU_SM);
|
|
} else {
|
|
writel(TSU_SM_EN, priv->base + TSU_SM);
|
|
/*
|
|
* According to the HW manual (Rev.1.10, section 40.4.1 Procedure for
|
|
* Starting the TSU) we need to wait here 30us or more.
|
|
*/
|
|
usleep_range(30, 40);
|
|
|
|
writel(TSU_SM_OE | TSU_SM_EN, priv->base + TSU_SM);
|
|
/*
|
|
* According to the HW manual (Rev.1.10, section 40.4.1 Procedure for
|
|
* Starting the TSU) we need to wait here 50us or more.
|
|
*/
|
|
usleep_range(50, 60);
|
|
}
|
|
|
|
pm_runtime_put_autosuspend(dev);
|
|
}
|
|
|
|
static int rzg3s_thermal_change_mode(struct thermal_zone_device *tz,
|
|
enum thermal_device_mode mode)
|
|
{
|
|
struct rzg3s_thermal_priv *priv = thermal_zone_device_priv(tz);
|
|
|
|
if (priv->mode == mode)
|
|
return 0;
|
|
|
|
rzg3s_thermal_set_mode(priv, mode);
|
|
priv->mode = mode;
|
|
|
|
return 0;
|
|
}
|
|
|
|
static const struct thermal_zone_device_ops rzg3s_tz_of_ops = {
|
|
.get_temp = rzg3s_thermal_get_temp,
|
|
.change_mode = rzg3s_thermal_change_mode,
|
|
};
|
|
|
|
static int rzg3s_thermal_read_calib(struct rzg3s_thermal_priv *priv)
|
|
{
|
|
struct device *dev = priv->dev;
|
|
u32 val;
|
|
int ret;
|
|
|
|
ret = pm_runtime_resume_and_get(dev);
|
|
if (ret)
|
|
return ret;
|
|
|
|
val = readl(priv->base + OTPTSUTRIM_REG(0));
|
|
if (val & OTPTSUTRIM_EN_MASK)
|
|
priv->calib0 = FIELD_GET(OTPTSUTRIM_MASK, val);
|
|
else
|
|
priv->calib0 = SW_CALIB0_VAL;
|
|
|
|
val = readl(priv->base + OTPTSUTRIM_REG(1));
|
|
if (val & OTPTSUTRIM_EN_MASK)
|
|
priv->calib1 = FIELD_GET(OTPTSUTRIM_MASK, val);
|
|
else
|
|
priv->calib1 = SW_CALIB1_VAL;
|
|
|
|
pm_runtime_put_autosuspend(dev);
|
|
|
|
return 0;
|
|
}
|
|
|
|
static int rzg3s_thermal_probe(struct platform_device *pdev)
|
|
{
|
|
struct rzg3s_thermal_priv *priv;
|
|
struct device *dev = &pdev->dev;
|
|
int ret;
|
|
|
|
priv = devm_kzalloc(dev, sizeof(*priv), GFP_KERNEL);
|
|
if (!priv)
|
|
return -ENOMEM;
|
|
|
|
priv->base = devm_platform_ioremap_resource(pdev, 0);
|
|
if (IS_ERR(priv->base))
|
|
return PTR_ERR(priv->base);
|
|
|
|
priv->channel = devm_iio_channel_get(dev, "tsu");
|
|
if (IS_ERR(priv->channel))
|
|
return dev_err_probe(dev, PTR_ERR(priv->channel), "Failed to get IIO channel!\n");
|
|
|
|
priv->rstc = devm_reset_control_get_exclusive_deasserted(dev, NULL);
|
|
if (IS_ERR(priv->rstc))
|
|
return dev_err_probe(dev, PTR_ERR(priv->rstc), "Failed to get reset!\n");
|
|
|
|
priv->dev = dev;
|
|
priv->mode = THERMAL_DEVICE_DISABLED;
|
|
platform_set_drvdata(pdev, priv);
|
|
|
|
pm_runtime_set_autosuspend_delay(dev, 300);
|
|
pm_runtime_use_autosuspend(dev);
|
|
ret = devm_pm_runtime_enable(dev);
|
|
if (ret)
|
|
return dev_err_probe(dev, ret, "Failed to enable runtime PM!\n");
|
|
|
|
ret = rzg3s_thermal_read_calib(priv);
|
|
if (ret)
|
|
return dev_err_probe(dev, ret, "Failed to read calibration data!\n");
|
|
|
|
priv->tz = devm_thermal_of_zone_register(dev, 0, priv, &rzg3s_tz_of_ops);
|
|
if (IS_ERR(priv->tz))
|
|
return dev_err_probe(dev, PTR_ERR(priv->tz), "Failed to register thermal zone!\n");
|
|
|
|
ret = devm_thermal_add_hwmon_sysfs(dev, priv->tz);
|
|
if (ret)
|
|
return dev_err_probe(dev, ret, "Failed to add hwmon sysfs!\n");
|
|
|
|
return 0;
|
|
}
|
|
|
|
static int rzg3s_thermal_suspend(struct device *dev)
|
|
{
|
|
struct rzg3s_thermal_priv *priv = dev_get_drvdata(dev);
|
|
|
|
rzg3s_thermal_set_mode(priv, THERMAL_DEVICE_DISABLED);
|
|
|
|
return reset_control_assert(priv->rstc);
|
|
}
|
|
|
|
static int rzg3s_thermal_resume(struct device *dev)
|
|
{
|
|
struct rzg3s_thermal_priv *priv = dev_get_drvdata(dev);
|
|
int ret;
|
|
|
|
ret = reset_control_deassert(priv->rstc);
|
|
if (ret)
|
|
return ret;
|
|
|
|
if (priv->mode != THERMAL_DEVICE_DISABLED)
|
|
rzg3s_thermal_set_mode(priv, priv->mode);
|
|
|
|
return 0;
|
|
}
|
|
|
|
static const struct dev_pm_ops rzg3s_thermal_pm_ops = {
|
|
SYSTEM_SLEEP_PM_OPS(rzg3s_thermal_suspend, rzg3s_thermal_resume)
|
|
};
|
|
|
|
static const struct of_device_id rzg3s_thermal_dt_ids[] = {
|
|
{ .compatible = "renesas,r9a08g045-tsu" },
|
|
{ /* sentinel */ }
|
|
};
|
|
MODULE_DEVICE_TABLE(of, rzg3s_thermal_dt_ids);
|
|
|
|
static struct platform_driver rzg3s_thermal_driver = {
|
|
.driver = {
|
|
.name = "rzg3s-thermal",
|
|
.of_match_table = rzg3s_thermal_dt_ids,
|
|
.pm = pm_ptr(&rzg3s_thermal_pm_ops),
|
|
},
|
|
.probe = rzg3s_thermal_probe,
|
|
};
|
|
module_platform_driver(rzg3s_thermal_driver);
|
|
|
|
MODULE_DESCRIPTION("Renesas RZ/G3S Thermal Sensor Unit Driver");
|
|
MODULE_AUTHOR("Claudiu Beznea <claudiu.beznea.uj@bp.renesas.com>");
|
|
MODULE_LICENSE("GPL");
|