Linux-6.18.2/tools/perf/pmu-events/arch/arm64/fujitsu/monaka/gcycle.json
2025-12-23 20:06:59 +08:00

98 lines
3.9 KiB
JSON

[
{
"EventCode": "0x0880",
"EventName": "GCYCLES",
"BriefDescription": "This event counts the number of cycles at 100MHz."
},
{
"EventCode": "0x0890",
"EventName": "FL0_GCYCLES",
"BriefDescription": "This event counts the number of cycles where the measured core is staying in the Frequency Level 0."
},
{
"EventCode": "0x0891",
"EventName": "FL1_GCYCLES",
"BriefDescription": "This event counts the number of cycles where the measured core is staying in the Frequency Level 1."
},
{
"EventCode": "0x0892",
"EventName": "FL2_GCYCLES",
"BriefDescription": "This event counts the number of cycles where the measured core is staying in the Frequency Level 2."
},
{
"EventCode": "0x0893",
"EventName": "FL3_GCYCLES",
"BriefDescription": "This event counts the number of cycles where the measured core is staying in the Frequency Level 3."
},
{
"EventCode": "0x0894",
"EventName": "FL4_GCYCLES",
"BriefDescription": "This event counts the number of cycles where the measured core is staying in the Frequency Level 4."
},
{
"EventCode": "0x0895",
"EventName": "FL5_GCYCLES",
"BriefDescription": "This event counts the number of cycles where the measured core is staying in the Frequency Level 5."
},
{
"EventCode": "0x0896",
"EventName": "FL6_GCYCLES",
"BriefDescription": "This event counts the number of cycles where the measured core is staying in the Frequency Level 6."
},
{
"EventCode": "0x0897",
"EventName": "FL7_GCYCLES",
"BriefDescription": "This event counts the number of cycles where the measured core is staying in the Frequency Level 7."
},
{
"EventCode": "0x0898",
"EventName": "FL8_GCYCLES",
"BriefDescription": "This event counts the number of cycles where the measured core is staying in the Frequency Level 8."
},
{
"EventCode": "0x0899",
"EventName": "FL9_GCYCLES",
"BriefDescription": "This event counts the number of cycles where the measured core is staying in the Frequency Level 9."
},
{
"EventCode": "0x089A",
"EventName": "FL10_GCYCLES",
"BriefDescription": "This event counts the number of cycles where the measured core is staying in the Frequency Level 10."
},
{
"EventCode": "0x089B",
"EventName": "FL11_GCYCLES",
"BriefDescription": "This event counts the number of cycles where the measured core is staying in the Frequency Level 11."
},
{
"EventCode": "0x089C",
"EventName": "FL12_GCYCLES",
"BriefDescription": "This event counts the number of cycles where the measured core is staying in the Frequency Level 12."
},
{
"EventCode": "0x089D",
"EventName": "FL13_GCYCLES",
"BriefDescription": "This event counts the number of cycles where the measured core is staying in the Frequency Level 13."
},
{
"EventCode": "0x089E",
"EventName": "FL14_GCYCLES",
"BriefDescription": "This event counts the number of cycles where the measured core is staying in the Frequency Level 14."
},
{
"EventCode": "0x089F",
"EventName": "FL15_GCYCLES",
"BriefDescription": "This event counts the number of cycles where the measured core is staying in the Frequency Level 15."
},
{
"EventCode": "0x08A0",
"EventName": "RETENTION_GCYCLES",
"BriefDescription": "This event counts the number of cycles where the measured core is staying in the RETENTION state."
},
{
"EventCode": "0x08A1",
"EventName": "RETENTION_COUNT",
"BriefDescription": "This event counts the number of changes from the normal state to the RETENTION state."
}
]